Transcranial doppler sonography is not a valid diagnostic tool for detection of basilar artery stenosis or in-stent restenosis: a retrospective diagnostic study

2017 | journal article

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Transcranial doppler sonography is not a valid diagnostic tool for detection of basilar artery stenosis or in-stent restenosis: a retrospective diagnostic study​
Koh, W. ; Kallenberg, K. ; Karch, A. ; Frank, T. ; Knauth, M. ; Bähr, M.   & Liman, J. ​ (2017) 
BMC Neurology17(1) art. 89​.​ DOI: https://doi.org/10.1186/s12883-017-0872-8 

Documents & Media

12883_2017_Article_872.pdf511.95 kBAdobe PDF

License

Published Version

Attribution 4.0 CC BY 4.0

Details

Authors
Koh, Woori ; Kallenberg, Kai ; Karch, André ; Frank, Tobias ; Knauth, Michael ; Bähr, Mathias ; Liman, Jan 
Abstract
Background There are contradictory reports concerning the validity of transcranial sonography (TCD and TCCS) for examinations of the basilar artery. Here we investigated sensitivity and specificity of transcranial sonography for the detection of basilar artery stenosis and in-stent-restenosis compared to cerebral angiography. Methods We analyzed data of 104 examinations of the basilar artery. The association between sonographic peak systolic velocity (PSV) and degree of stenosis obtained by cerebral angiography was evaluated applying Spearman’s correlation coefficient. Receiver Operating Characteristics (ROC) curves and areas under the curve (AUC) were calculated for the detection of a ≥50% stenosis defined by angiography. Optimal cut-off was derived using the Youden-index. Results A weak but statistically significant correlation between PSV and the degree of stenosis was found (n=104, rho=0.35, p<0.001). ROC analysis for a detection of ≥50% stenosis showed an AUC of 0.70, a sensitivity of 74.0% and a specificity of 65.0% at the optimal cut off of 124 cm/s. Results were consistent when analyzing examinations done in stented and unstented arteries separately (TCD VS DSA/CTA in unstented artery: AUC=0.66, sensitivity 61.0%, specificity 65.0%, TCD/TCCS VS DSA in stented artery: AUC=0.63, sensitivity 71.0%, specificity 82.0%). Comparing TCCS measurements exclusively to angiography, ROC analysis showed an AUC of 1.00 for the detection of an in-stent-restenosis ≥50% with a sensitivity and specificity of 100% when a PSV of 132 cm/s was used as a cut off value. Conclusion Validity of TCD in the assessment of basilar artery stenosis or in-stent restenosis is poor. First results for TCCS are promising, but due to the small samplesize further studies with larger samples sizes are warranted.
Issue Date
2017
Journal
BMC Neurology 
ISSN
1471-2377
Language
English

Reference

Citations


Social Media