Intracycle power and ventilation mode as potential contributors to ventilator-induced lung injury

2021-11-01 | journal article; research paper. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Intracycle power and ventilation mode as potential contributors to ventilator-induced lung injury​
Marini, J. J.; Crooke, P. S.; Tawfik, P.; Chatburn, R. L.; Dries, D. J. & Gattinoni, L.​ (2021) 
Intensive Care Medicine Experimental9(1) art. 55​.​ DOI: https://doi.org/10.1186/s40635-021-00420-9 

Documents & Media

40635_2021_Article_420.pdf1.09 MBAdobe PDF

License

Published Version

Attribution 4.0 CC BY 4.0

Details

Authors
Marini, John J.; Crooke, Philip S.; Tawfik, Pierre; Chatburn, Robert L.; Dries, David J.; Gattinoni, Luciano
Abstract
Abstract Background High rates of inflation energy delivery coupled with transpulmonary tidal pressures of sufficient magnitude may augment the risk of damage to vulnerable, stress-focused units within a mechanically heterogeneous lung. Apart from flow amplitude, the clinician-selected flow waveform, a relatively neglected dimension of inflation power, may distribute inflation energy of each inflation cycle non-uniformly among alveoli with different mechanical properties over the domains of time and space. In this initial step in modeling intracycle power distribution, our primary objective was to develop a mathematical model of global intracycle inflation power that uses clinician-measurable inputs to allow comparisons of instantaneous ICP profiles among the flow modes commonly encountered in clinical practice: constant, linearly decelerating, exponentially decelerating (pressure control), and spontaneous (sinusoidal). Methods We first tested the predictions of our mathematical model of passive inflation with the actual physical performance of a mechanical ventilator–lung system that simulated ventilation to three types of patients: normal, severe ARDS, and severe airflow obstruction. After verification, model predictions were then generated for 5000 ‘virtual ARDS patients’. Holding constant the tidal volume and inflation time between modes, the validated model then varied the flow profile and quantitated the resulting intensity and timing of potentially damaging ‘elastic’ energy and intracycle power (pressure–flow product) developed in response to random combinations of machine settings and severity levels for ARDS. Results Our modeling indicates that while the varied flow patterns ultimately deliver similar total amounts of alveolar energy during each breath, they differ profoundly regarding the potentially damaging pattern with which that energy distributes over time during inflation. Pressure control imposed relatively high maximal intracycle power. Conclusions Flow amplitude and waveform may be relatively neglected and modifiable determinants of VILI risk when ventilating ARDS.
Issue Date
1-November-2021
Publisher
Springer International Publishing
Journal
Intensive Care Medicine Experimental 
Language
English

Reference

Citations


Social Media