Rapid detection of human coronavirus NL63 by isothermal reverse transcription recombinase polymerase amplification

2022 | journal article. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Rapid detection of human coronavirus NL63 by isothermal reverse transcription recombinase polymerase amplification​
Dorendorf, A.; Bachmann, I.; Spiegel, M.; Abd El Wahed, A. ; Dame, G. & Hufert, F.​ (2022) 
Journal of Clinical Virology Plus2(4) art. 100115​.​ DOI: https://doi.org/10.1016/j.jcvp.2022.100115 

Documents & Media

License

Published Version

Usage license

Details

Authors
Dorendorf, Aline; Bachmann, Iris; Spiegel, Martin; Abd El Wahed, Ahmed ; Dame, Gregory; Hufert, Frank
Abstract
Background Human coronaviruses are one of the leading causes for respiratory tract infections and for frequent primary care consultation. The human coronavirus NL63 (HCoV..µNL63) is one representative of the seasonal coronaviruses and capable of infecting the upper and lower respiratory tract and causative agent for croup in children. Objectives For fast detection of HCoV-NL63, we developed an isothermal reverse transcription recombinase polymerase amplification (RT-RPA) assay. Study design The analytical sensitivities of the RT-RPA assay were identified for in vitro transcribed ribonucleic acid (RNA) and for genomic viral RNA from cell culture supernatant. Moreover, specificity was tested with nucleic acids from other human coronaviruses and a variety of clinically relevant respiratory viruses. Finally, a clinical nasopharyngeal swab sample with spiked genomic viral HCoV-NL63 RNA was analyzed. Results Our HCoV-NL63 RT-RPA assay is highly specific and has an analytical sensitivity of 13 RNA molecules/reaction for in vitro transcribed RNA. For genomic viral RNA from cell culture supernatant spiked into a clinical nasopharyngeal swab sample the assay...s analytical sensitivity is 170 RNA molecules/reaction. The assay shows amplification of the lowest detectable target copy number after 8 minutes and 7 minutes, respectively. Conclusions We were able to design a sensitive and specific RT-RPA assay for the detection of HCoV-NL63. Additionally, the assay is characterized by short duration, isothermal amplification, and simple instrumentation.
Issue Date
2022
Journal
Journal of Clinical Virology Plus 
Organization
Deutsches Primatenzentrum 
ISSN
2667-0380
Language
English
Sponsor
http://dx.doi.org/10.13039/501100002347 Bundesministerium für Bildung und Forschung

Reference

Citations


Social Media