A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom

2013 | journal article. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom​
Otton, J.; Morton, G.; Schuster, A.; Bigalke, B.; Marano, R.; Olivotti, L. & Nagel, E. et al.​ (2013) 
Journal of Cardiovascular Computed Tomography7(2) pp. 117​-124​.​ DOI: https://doi.org/10.1016/j.jcct.2013.01.016 

Documents & Media

License

Published Version

Special user license Goescholar License

Details

Authors
Otton, James; Morton, Geraint; Schuster, Andreas; Bigalke, Boris; Marano, Riccardo; Olivotti, Luca; Nagel, Eike; Chiribiri, Amedeo
Abstract
Background: Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. Objective: We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. Methods: We used a customized MR imaging and CT compatible dynamic myocardial perfusion phantom to represent the human circulation. CT perfusion studies were performed with a Philips iCT (256 slice) CT, with isotropic resolution of 0.6 mm(3). MR perfusion was performed with k-t SENSE acceleration at 3 T and spatial resolution of 1.2 x 1.2 x 10 mm. The image contrast between normal and underperfused myocardial compartments was quantified at various perfusion and photon energy settings. Noise estimates were based on published clinical data. Results: Contrast by CTP highly depends on photon energy and also timing of imaging within the myocardial perfusion upslope. For an identical myocardial perfusion deficit, the native image contrast-to-noise ratio (CNR) generated by CT and MR are similar. If slice averaging is used, the CNR of a perfusion deficit is expected to be greater for CTP than MR perfusion (MRP). Perfect timing during single time point CTP imaging is difficult to achieve, and CNR by CT decreases by 24%-31% two seconds from the optimal imaging time point. Although single-phase CT perfusion offers higher spatial resolution, MRP allows multiple time point sampling and quantitative analysis. Conclusion: The ability of CTP and current optimal MRP techniques to detect simulated myocardial perfusion deficits is similar. Crown Copyright (c) 2013 Published by Elsevier Inc. on behalf of Society of Cardiovascular Computed Tomography. All rights reserved.