Dendritic Polyglycerolsulfate Near Infrared Fluorescent (NIRF) Dye Conjugate for Non-Invasively Monitoring of Inflammation in an Allergic Asthma Mouse Model

2013 | journal article. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Dendritic Polyglycerolsulfate Near Infrared Fluorescent (NIRF) Dye Conjugate for Non-Invasively Monitoring of Inflammation in an Allergic Asthma Mouse Model​
Biffi, S.; Dal Monego, S.; Dullin, C.; Garrovo, C.; Bosnjak, B.; Licha, K. & Welker, P. et al.​ (2013) 
PLoS ONE8(2) art. e57150​.​ DOI: https://doi.org/10.1371/journal.pone.0057150 

Documents & Media

journal.pone.0057150.pdf792.93 kBAdobe PDF

License

Published Version

Attribution 2.5 CC BY 2.5

Details

Authors
Biffi, Stefania; Dal Monego, Simeone; Dullin, Christian; Garrovo, Chiara; Bosnjak, Berislav; Licha, Kai; Welker, Pia; Epstein, Michelle M.; Alves, Frauke 
Abstract
Background: Non-invasive in vivo imaging strategies are of high demand for longitudinal monitoring of inflammation during disease progression. In this study we present an imaging approach using near infrared fluorescence (NIRF) imaging in combination with a polyanionic macromolecular conjugate as a dedicated probe, known to target L- and P-selectin and C3/C5 complement factors. Methodology/Principal Findings: We investigated the suitability of dendritic polyglycerol sulfates (dPGS), conjugated with a hydrophilic version of the indocyanine green label with 6 sulfonate groups (6S-ICG) to monitor sites of inflammation using an experimental mouse model of allergic asthma. Accumulation of the NIRF-conjugated dPGS (dPGS-NIRF) in the inflamed lungs was analyzed in and ex vivo in comparison with the free NIRF dye using optical imaging. Commercially available smart probes activated by matrix metalloproteinase's (MMP) and cathepsins were used as a comparative control. The fluorescence intensity ratio between lung areas of asthmatic and healthy mice was four times higher for the dPGS in comparison to the free dye in vivo at four hrs post intravenous administration. No significant difference in fluorescence intensity between healthy and asthmatic mice was observed 24 hrs post injection for dPGS-NIRF. At this time point ex-vivo scans of asthmatic mice confirmed that the fluorescence within the lungs was reduced to approximately 30% of the intensity observed at 4 hrs post injection. Conclusions/Significance: Compared with smart-probes resulting in a high fluorescence level at 24 hrs post injection optical imaging with dPGS-NIRF conjugates is characterized by fast uptake of the probe at inflammatory sites and represents a novel approach to monitor lung inflammation as demonstrated in mice with allergic asthma.
Issue Date
2013
Status
published
Publisher
Public Library Science
Journal
PLoS ONE 
ISSN
1932-6203
Sponsor
European Commission through an FP7- IAPP Marie Curie Action [GA 230739]

Reference

Citations


Social Media