Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation

2016 | journal article. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation​
Negro, F.; Muceli, S.; Castronovo, A. M.; Holobar, A. & Farina, D.​ (2016) 
Journal of Neural Engineering13(2) art. 026027​.​ DOI: https://doi.org/10.1088/1741-2560/13/2/026027 

Documents & Media

License

GRO License GRO License

Details

Authors
Negro, Francesco; Muceli, Silvia; Castronovo, Anna Margherita; Holobar, Ales; Farina, Dario
Abstract
Objective. The study of motor unit behavior has been classically performed by selective recording systems of muscle electrical activity (EMG signals) and decomposition algorithms able to discriminate between individual motor unit action potentials from multi -unit signals. In this study, we provide a general framework for the decomposition of multi-channel intramuscular and surface EMG signals and we extensively validate this approach with experimental recordings. Approach. First, we describe the conditions under which the assumptions of the convolutive blind separation model are satisfied. Second, we propose an approach of convolutive sphering of the observations followed by an iterative extraction of the sources. This approach is then validated using intramuscular signals recorded by novel multi-channel thin-film electrodes on the Abductor Digiti Minimi of the hand and Tibilias Anterior muscles, as well as on high -density surface EMG signals recorded by electrode grids on the First Dorsal Interosseous muscle. The validation was based on the comparison with the gold standard of manual decomposition (for intramuscular recordings) and on the two -source method (for comparison of intramuscular and surface EMG recordings) for the three human muscles and contraction forces of up to 90% MVC. Main results. The average number of common sources identified for the validation was 14 7 (averaged across all trials and subjects and all comparisons), with a rate of agreement in their discharge timings of 92.8 +/- 3.2%. The average Decomposability Index, calculated on the automatic decomposed signals, was 16.0 +/- 2.2 (7.3-44.1). For comparison, the same index calculated on the manual decomposed signals was 15.0 +/- 3.0 (6.3-76.6). Significance. These results show that the method provides a solid framework for the decomposition of multi-channel invasive and non-invasive EMG signals that allows the study of the behavior of a large number of concurrently active motor units.
Issue Date
2016
Status
published
Publisher
Iop Publishing Ltd
Journal
Journal of Neural Engineering 
ISSN
1741-2552; 1741-2560

Reference

Citations


Social Media