Enhanced accuracy of kinetic information from CT-CPMG experiments by transverse rotating-frame spectroscopy

2013 | journal article; research paper. A publication with affiliation to the University of Göttingen.

Jump to: Cite & Linked | Documents & Media | Details | Version history

Cite this publication

​Enhanced accuracy of kinetic information from CT-CPMG experiments by transverse rotating-frame spectroscopy​
Ban, D. ; Mazur, A. ; Carneiro, M. G. ; Sabo, T. M. ; Giller, K. ; Koharudin, L. M. I. & Becker, S.  et al.​ (2013) 
Journal of Biomolecular NMR57(1) pp. 73​-82​.​ DOI: https://doi.org/10.1007/s10858-013-9769-z 

Documents & Media

License

GRO License GRO License

Details

Authors
Ban, David ; Mazur, Adam ; Carneiro, Marta G. ; Sabo, T. Michael ; Giller, Karin ; Koharudin, Leonardus M. I.; Becker, Stefan ; Gronenborn, Angela M.; Griesinger, Christian ; Lee, Donghan 
Abstract
Micro-to-millisecond motions of proteins transmit pivotal signals for protein function. A powerful technique for the measurement of these motions is nuclear magnetic resonance spectroscopy. One of the most widely used methodologies for this purpose is the constant-time Carr-Purcell-Meiboom-Gill (CT-CPMG) relaxation dispersion experiment where kinetic and structural information can be obtained at atomic resolution. Extraction of accurate kinetics determined from CT-CPMG data requires refocusing frequencies that are much larger than the nuclei's exchange rate between states. We investigated the effect when fast processes are probed by CT-CPMG experiments via simulation and show that if the intrinsic relaxation rate is not known a priori the extraction of accurate kinetics is hindered. Errors on the order of 50 % in the exchange rate are attained when processes become fast, but are minimized to 5 % with a priori information. To alleviate this shortcoming, we developed an experimental scheme probing with large amplitude spin-lock fields, which specifically contains the intrinsic proton longitudinal Eigenrelaxation rate. Our approach was validated with ubiquitin and the Oscillatoria agardhii agglutinin (OAA). For OAA, an underestimation of 66 % in the kinetic rates was observed if is not included during the analysis of CT-CPMG data and result in incorrect kinetics and imprecise amplitude information. This was overcome by combining CT-CPMG with measured with a high power R-1 rho experiment. In addition, the measurement of removes the ambiguities in choosing between different models that describe CT-CPMG data.
Issue Date
2013
Publisher
Springer
Journal
Journal of Biomolecular NMR 
ISSN
0925-2738

Reference

Citations


Social Media